Estudo de requisitos para datacenters e salas industriais para sistemas de tecnologia e automação
DOI:
https://doi.org/10.26853/Refas_ISSN-2359-182X_v10n01_01Keywords:
Centro de dados, Monitoramento, Salas Controladas, Normas de TecnologiaAbstract
Within the industrial environment it is of evident importance that the environment in which technology systems (such as servers, switches, routers) and automation systems (such as PLCs) are properly supported, to avoid impacts due to infrastructure problems, such as lack of energy, failure in HVAC systems (generating higher temperatures than recommended for this equipment). To prevent these problems, the industries may have several equipment and systems to protect and monitor these rooms. However, there is no standard in Brazil establishing models to be followed on this subject so that a technology room or a Datacenter has an adequate availability for the systems supported on it, and even outside Brazil, the standardization may not be adequate to the particularities from different countries and add some that may not be significant for others. Establishing standards for these rooms bring a significant benefit to industries, since these are increasingly using technologies for their production, security, and emergency systems, thus requiring maximus availability, while other rooms may only support small complexity systems and/or that do not have the same criticality for the company, therefore they do not need such a high level of availability.
Downloads
References
ABNT. NBR ISO/IEC 27002: Tecnologia da Informação - Técnicas de Segurança - Código de Prática para Gestão da Segurança da Informação. ABNT, 2013a.
ABNT. NBR 14.565: Cabeamento estruturado para edifícios comerciais e data centers. ABNT, 2013b.
ASHRAE. Thermal Guidelines for Data Processing Environments. 1 Edition, Atlanta, 2004.
BARRETO, A., FERREIRA, I., TRAVESSA, S. UPS: Sistemas Ininterrupto de Energia (Nobreak) – Aplicação, Especificação e Dimensionamento. UNISUL, Palhoça, Santa Catarina, 2018.
BHATIA, A. HVAC Cooling Systems for Data Centers. Continuing Education and Development, Inc., 2015.
FACCIONI FILHO, M. Conceitos e infraestrutura de datacenters. Palhoça: UnisulVirtual, 2016.
GUGGARI, S., AGONAFER, D., BELADY, C., et al.. “A hybrid methodology for the optimization of data center room layout”, International Electronic Packaging Technical Conference and Exhibition, v. 36908, pp. 605–612, 2003.
HPE. “HP BladeSystem Matrix - Specifications”. Disponível em https://support.hpe.com/hpesc/public/docDisplay?docId=c02440915&docLocale=en_US, 2022a. Acessado em 18/03/2022.
HPE. “HPE 48U 600mmx1075mm G2 Enterprise Shock Rack”. Disponível em https://buy.hpe.com/us/en/rack-power-infrastructure/racks/server-racks/racks/hpe-g2-enterprise-series-racks/hpe-48u-600mmx1075mm-g2-enterprise-shock-rack/p/P9K50A, 2022b. Acessado em 05/04/2022.
MARIN, P. S. Data centers: Desvendando cada passo: Conceitos, projeto, infraestrutura física e eficiência energética. Érica, 2011.
MARIN, P. S. Data centers - Engenharia. Unisul Virtual, 2016.
MARTINS, A., SAUKAS, E., ZANARDO, J. “SCAI: Sistema de Controle de Acesso para os Requisitos da Saúde”, Anais do IX Congresso Brasileiro de Informática em Saúde, 2004.
MOREIRA, N. S. Segurança mínima: uma visão corporativa da segurança de informações. Axel Books, 2001.
NETWORK ENERGY. “Manutenção de Nobreaks: prevenção e periodicidade”. Disponível em https://networkenergy.com.br/blog/manutencao-de-nobreaks-prevencao-e-periodicidade, 2022. Acessado em 03/05/2022.
NFPA, N. F. P. A. Standard on Clean Agent Fire Extinguishing Systems. NFPA, 2022.
ONS. “Indicadores de Desempenho do SIN – Número de Perturbações Ocorridas na Rede Básica”. Disponível em http://www.ons.org.br/Paginas/resultados-da-operacao/qualidade-do-suprimento-paineis.aspx, 2022. Acessado em 20/04/2022.
PARASURAMAN, R., MOULOUA, M. Automation and Human Performance: Theory and Applications. Lawrence Erlbaum Associates, Mahwah, NJ, USA, 1996.
ROSA, R. C., ARANDA, M. C., ANTONIOLLI, P. D. “Segurança Física em Datacenters: Estudo de Caso”, REFAS - Revista Fatec Zona Sul, 2017.
SATCHELL, P. Innovation and Automation. Ashgate Publishing, Aldershot England, 1998.
SILVA, M. C. “Automatização dos Grupos Geradores da Estação de Bombas VI da Unidade de Germano da Samarco Mineração”, UFOP, Ouro Preto, Minas Gerais, 2017.
STEIN, J., BRANDON, G. “Data Center Controls Reliability”, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), 2018.
TELECOMMUNICATIONS INDUSTRY ASSOCIATION. “THE GLOBAL DATA CENTER STANDARD”. Disponível em https://tiaonline.org/wp-content/uploads/dlm_uploads/2021/01/TIA-942-Standard_OnePager-110220.pdf, a.
TELECOMMUNICATIONS INDUSTRY ASSOCIATION. “TIA-942 CERTIFIED DATA CENTERS IN BRAZIL”. Disponível em https://tiaonline.org/942-datacenters/?fwp_regions=south-america&fwp_country=brazil, b.
UPTIME INSTITUTE. “Accredited Tier Designer Technical Paper Series: Continuous Cooling”, 2017.
VERAS, M. Datacenter: Componente Central da Infraestrutura de TI. BRASPORT, 2009.
WINROTH, M., SÄFSTEN, K., STAHRE, J. “Automation strategies: existing theory or ad hoc decisions?” International Journal of Manufacturing Technology and Management, 2007.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Refas - Revista Fatec Zona Sul

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
1 - As fontes dos dados, as autorizações pertinentes e os textos publicados na revista são de inteira responsabilidade de seus autores.
2 - É permitida a reprodução, desde que citada a fonte e o autor.
3 - Após o artigo aprovado, o autor principal deverá enviar declaração, conforme o modelo:
Refas - Revista Fatec Zona Sul
Autorização par publicação
(Nome do autor), (no caso de vários autores citar todos), autorizo (ou autorizam, no caso de diversos autores) a publicação do artigo (nome do artigo), com exclusividade para a primeira publicação pela Revista Fatec Zona Sul, em meio eletrônico.
A contribuição é original e inédita, e não está sendo avaliada para publicação por outra revista; caso contrário, deve-se justificar em "Comentários ao editor".
Dados de todos os autores:
Nome completo:
Instituição:
E-mail:
Telefone:
Obs.: Informar os códigos dos serviços DDD e DDI.
Assinatura do autor principal: ____________________________________
Aviso de Direito Autoral
Autores que publicam nesta revista concordam com os seguintes termos:
a) Autores têm autorização para assumir contratos adicionais separadamente, para distribuição não-exclusiva da versão do trabalho publicada nesta revista (ex.: publicar em repositório institucional ou como capítulo de livro), com reconhecimento de autoria e publicação inicial nesta revista.
b) Autores têm permissão e são estimulados a publicar e distribuir seu trabalho online (ex.: em repositórios institucionais ou na sua página pessoal) a qualquer ponto antes ou durante o processo editorial, já que isso pode gerar alterações produtivas, bem como aumentar o impacto e a citação do trabalho publicado.
c)Autores mantém os direitos autorais e concedem à revista o direito de primeira publicação, com o trabalho simultaneamente licenciado sob a Licença Creative Commons CC Attribution-NonCommercial-NoDerivatives 4.0, acessável em Licença Creative Commons Attribution, que permite o compartilhamento do trabalho com reconhecimento da autoria e publicação inicial nesta revista.